Symbia Intevo Bold
More CT for your SPECT/CT
Symbia Intevo Bold™ combines high-performance CT with advanced SPECT imaging to accommodate even the most challenging situations. For those who want more from their system, Symbia Intevo Bold offers the flexibility to take your capabilities even further with a range of unique and powerful SPECT and CT options.
. More clarity for more patients
. Dose reduction without compromise
. The right care at the right time
More clarity for more patients
We re-engineered SPECT/CT bone imaging to use CT as the frame-of-reference during image reconstruction. The higher image resolution achieved from xSPECT Bone™ technology enables you to better localize and characterize disease for a more accurate representation of each patient’s condition.
As patient populations continue to age, the growing presence of metal implants and pacemakers adds complexity to imaging. iMAR, our CT metal-artifact-reduction technique, helps improve both CT and SPECT attenuation correction in these cases.2 xSPECT Bone and iMAR can easily be combined for even greater image clarity.
Dose reduction without compromise
For quick and conclusive answers to clinical questions, you need the best image for each patient. However, striking the right balance between image quality and radiation dose can be a challenge, particularly given today’s diverse patient population. Our proprietary CT image reconstruction software and hardware, SAFIRE, lets you accomplish this—quickly and easily.3
The right care at the right time
Adding reliable quantification to your clinical routine can facilitate quicker consensus and generate greater consistency across your institution. Our xSPECT Quant™ and Broad Quantification™ technologies generate highly accurate and reliable measurements to support early diagnoses and optimal therapeutic strategies for a wide array of clinical indications.
Technical Specifications
Gantry |
|
Tunnel opening | 70 cm |
Tunnel length | 89 cm |
CT |
|
Generator power | 50 kW |
Rotation time | up to 0.5 s |
Tube voltage | 80, 110, 130 kv |
Iterative reconstruction | SAFIRE3, 4 |
Metal artifact reduction | iMAR2, 4 |
Slices | 16/321 |
SPECT |
|
Crystal thickness | 3/8” or 5/8” |
Detector dimension (FOV) | 53.3 x 38.7 cm |
Energy range | 35-588 keV |
System Sensitivity (LEHR at 10 cm) | 202 cpm/μCi |
Acquisition modes | Static, dynamic, gated, SPECT, gated SPECT, dynamic SPECT, whole-body, whole-body SPECT, SPECT/CT, xSPECT™ |
Quantitative accuracy | ≤ 5%4, 5 |