همراه سلامت و درمان کشور
Your Advanced Healthcare Partner
تهران، خیابان آرژانتین
بلوار الوند، خ35، پلاک8
No8 , 35th St. , Alvand Blv.
Argentina St. , Tehran
واحد فروش :
88651948-9 021
Sales Deptartment :
88651948-9 021
شنبه - چهارشنبه : 8:30 - 16:30
پنجشنبه : 8:30 - 12:30
Saturday - Wednesday : 8:30 - 16:30
Thursday : 8:30 - 12:30

SOMATOM go.Open Pro

The future is in motion

Introducing SOMATOM go.Open Pro – an advanced CT simulator that delivers accurate, reproducible patient modeling for treatments and individualized care. With a unique detector width, super soft-tissue contrast, and intelligent 4D CT with breathing adaptation, it achieves exceptional clarity for confident treatment planning. Input from RT specialists guided the design, so the fully integrated hardware and software are tailored to your requirements. These pioneering features, combined with data synchronization across all components, allow you to master challenging cases and devote more time to your patients.

SOMATOM go.Open Pro helps you expand precision medicine and make individualized therapy available to more patients. This is an advanced, intelligent CT simulator that helps you push the boundaries to fight the most challenging cancers.

        . Push the boundaries for challenging cases

        . Simulation reinvented

Clinical Use

Precision medicine, curative intent, and hypofractionated treatments hold enormous potential for patients. Yet they are only possible if the treatment planning data are absolutely precise. Many patients with conditions that present major challenges – such as the inability to hold one’s breath – miss out on the benefits because current CT simulation cannot manage the individual complexities they present. Poor-quality, imprecise information makes it especially difficult to target tumors and protect vital organs in these complex cases. In addition, error-prone workflows and time pressure can further hamper CT simulation.

We believe the future is in motion – and this belief shaped the development of SOMATOM go.Open Pro. This advanced CT simulator provides accurate, reproducible patient modeling that can break down the barriers to modern treatments and individualized care.

Difficulties in providing the best care for challenging cases

. Precision medicine, curative intent, and hypofractionated treatments have enormous potential

. Patients with cancers such as lung, liver, and head and neck cancer miss out on this potential because their cases are too challenging for existing CT systems

. Poor-quality, imprecise information makes it especially difficult to target tumors and protect healthy tissue

Push the boundaries for challenging cases

A CT simulator that provides exceptionally accurate and reproducible patient modeling could break down the barriers to moderntreatment methods and individualized patient care. SOMATOM go.Open Pro allows you to expand precision medicine and push the boundaries for challenging cases.

Push the boundaries for:

. Lung / liver imaging thanks to intelligent 4D CT with Direct i4D1

. Breast imaging thanks to shorter scan times for deep inspiration breath-hold with an extra-large detector and fast rotation time

. Head and neck imaging thanks to improved soft-tissue contrast with TwinSpiral Dual Energy2now with better motion management

Reduce unwarranted variations with high-quality OAR contours:

. Save time by eliminating manual step with DirectORGANS2– our AI-powered OAR contouring solution even for advanced structures (e.g. ribs, sternum and lung lobes contours)

. Easily access cardiac substructures to tailor your treatment plan with the goal of minimizing the risk of cardiac toxicities

SOMATOM go.Open Pro delivers exceptional clarity for highly confident planning. With it, you and everyone on your team can remain at the forefront of your field for years to come.

Push the boundaries for lung/liver imaging

Courtesy of MAASTRO clinic, The Netherlands

75% of the time patients breath irregularly which leads to artifacts3

Accuracy is essential when irradiating moving targets. Yet many traditional CT scanners cannot deliver the image quality necessary for this kind of treatment planning. During 4D acquisition, they produce either too much or too little data, which causes interpolation or motion artifacts.

Patients often breathe irregularly during 4D acquisition, which causes image artifacts.

Courtesy of MAASTRO clinic, The Netherlands

Reduce image artifacts for confident target margins with intelligent 4D CT thanks to Direct i4D

Direct i4Dis a 4D CT sequence that intelligently adapts to the patient’s breathing in real time. The algorithm monitors the breathing pattern throughout acquisition and reconstruction.

The result: Reducing unwarranted variations in the images can potentially decrease target margins.

Your benefits

. Robust and simple 4D image acquisition for every user

. Enables 4D images with virtually no artifacts related to incomplete breathing cycles

. More confident treatment planning with potential for smaller target margins

 

Courtesy of University Hospital Aarhus, Denmark

Direct i4D1 simplifies the 4D CT workflow and produces excellent results even for patients with irregular breathing patterns. Therefore, it helps to determine the best possible individual dose plan for RT.4Peter Albeck Qvistgaard
Head of radiography dept, Aarhus University Hospital, Aarhus, Denmark

Courtesy of Leopoldina Krankenhaus, Schweinfurt, Germany

 

World’s first CT simulator that generates contours for lung/liver cancer patients

DirectORGANS2 (Optimized Reconstruction based contours trained by Generative Adversarial Networks) is a revolutionary OAR contouring solution. It leverages optimized and standardized reconstruction parameters to deliver input to the deep learning based contouring solution. This process runs in parallel to the reconstruction of the image for target contouring.

The result: Save time and reduce unwarranted variations with high-quality contours that approach the level of consensus-based contours.

Your benefits

. Tailored treatment plans thanks to robust OAR contours, including ribs and lung lobes

. Reduce unwarranted variations with high-quality contours

. AI powered DirectORGANS2provides streamlined OAR contouring thanks to optimized reconstruction

Courtesy of Radiology Department, Hospital Particular de Viana do Castelo, Viana do Castelo, Portugal.

Push the boundaries for breast imaging

 

15% of patients don’t have sufficient breath-hold ability to be considered for DIBH5

Deep inspiration breath-hold (DIBH) is a widely accepted method of minimizing cardiac toxicity. Current CT simulators require a longer breath-hold (20 s)5 than is required in modern treatment techniques such as high-dose-rate therapies and fast cone beam CT.

Long breath-hold during CT simulation is uncomfortable for patients and can limit their access to tailored treatment.

Push the boundaries with reduced breath-hold times for deep inspiration breath-hold

By combining a 4-cm detector with fast rotation times (0.35 s2), SOMATOM go.Open Pro covers more of the patient’s anatomy in less time. An entire thorax scan takes less than 10 seconds.

The result: Reducing unwarranted variations in the images can potentially decrease target margins.

Your benefits

. Deep inspiration breath-hold for more patients thanks less than 10-second scan

. Confident breast contouring thanks to high image quality

. Enhanced patient comfort and improved access to tailored treatment

 

Courtesy of University Hospital Erlangen, Germany

 

Courtesy of University Hospital Zurich, Switzerland

 

The risk of cardiovascular disease increases by 7.4% per 1 Gy mean heart dose6

Minimizing cardiac toxicity in radiotherapy is highly related to accurate cardiac OAR contours. Especially when it comes to organs like the heart where movement artifacts in the images can be an additional problem.

Easily access cardiac substructures to tailor your treatment plan with the goal of minimizing the risk of cardiac toxicities.

Courtesy of Radiology Department, Hospital Particular de Viana do Castelo, Viana do Castelo, Portugal.

Cardiac chamber segmentation paves the way for research in the field of cardiac toxicity

Push the boundaries with AI-powered DirectORGANS2 for precise heart chamber contours in breast cancer patients.

The result: Easily access cardiac substructures to tailor your treatment plan with the goal of minimizing the risk of cardiac toxicities.

Your benefits

. Tailored treatment plans with high-quality OAR contours of cardiac substructures delivered directly from the CT simulator

. Straightforward cardiac chamber segmentation may pave the way for research in the field of cardiac toxicity

 

Courtesy of University Hospital Erlangen, Germany

 

Push the boundaries for head and neck imaging

 

The accuracy of target delineation for head and neck cancers is limited by the lack of soft-tissue contrast on CT.Wardman K et al. The feasibility of atlas-based automatic segmentation of MRI for H&N radiotherapy planning. J Applied Clin Med Phys. 2016; 17(4): 146–154.

 

Push the boundaries with TwinSpiral Dual Energy to improve target delineation

TwinSpiralDual Energyis a new form of dual-energy acquisition that uses a Tin Filter to achieve optimal spectral separation. By reducing scan times, it is especially suitable for cases involving motion.

The result: Precise target delineation thanks to improved soft-tissue contrast.

Your benefits

. Better soft-tissue contrast improves target delineation (e.g. at 40 keV)

. Less variability in target contouring7

 

SOMATOM go.Open Pro reinvents simulation

 

A straightforward, all-in-one solution for successful CT simulation

The flexible, intuitive system synchronizes data across all integrated components. It operates via one user interface and requires a single vendor service contract. This means you can spend less time managing CT simulation and more time focusing on your patients – in the comfortable and calming environment that SOMATOM go.Open Pro creates for them.

Your benefits

. Seamless and less error-prone CT simulation processes

. Optimal image quality for target contouring

. A comfortable and calming environment for patients, operators, and administrators

Technical Specifications

Bore size

85 cm

Scan Field-of-View (sFoV)

60 cm

Acquired slices/reconstruction slices

64/128

Z-axis coverage

3.84 cm

Rotation time

0.354, 0.5, 1.0 s

max. table load

227/3072kg (TG-66 compliant tables)

System footprint

4 m2/43 ft2 (surface area covered by gantry and moving table top)

Min. room requirement

17.3 m2/186.2 ft2

 

 

 

 

 

 

Scientific Talks and Publications

        . Intelligent 4D CT sequence scanning (i4DCT): Concept and performance evaluation

        . First scanner prototype implementation and phantom measurements of automated breathing signal‐guided 4D CT

More Information

Downloads

        . SOMATOM go.Open Pro brochure  6 MB

        . Dual Energy Cookbook  4 MB

        . 4D CT Imaging Cookbook  3 MB

        . DirectOrgans Whitepaper  6 MB

More Radiation Therapy Topics

        . SOMATOM go.Sim

        . SOMATOM CT Sliding Gantry

        . Computed Tomography

        . MRI in Therapy

        . Imaging for Radiation Therapy