همراه سلامت و درمان کشور
Your Advanced Healthcare Partner
تهران، خیابان آرژانتین
بلوار الوند، خ35، پلاک8
No8 , 35th St. , Alvand Blv.
Argentina St. , Tehran
واحد فروش :
88651948-9 021
Sales Deptartment :
88651948-9 021
شنبه - چهارشنبه : 8:30 - 16:30
پنجشنبه : 8:30 - 12:30
Saturday - Wednesday : 8:30 - 16:30
Thursday : 8:30 - 12:30

Symbia Intevo Bold

More CT for your SPECT/CT

Symbia Intevo Bold™ combines high-performance CT with advanced SPECT imaging to accommodate even the most challenging situations. For those who want more from their system, Symbia Intevo Bold offers the flexibility to take your capabilities even further with a range of unique and powerful SPECT and CT options.

        . More clarity for more patients

        . Dose reduction without compromise

        . The right care at the right time

More clarity for more patients

We re-engineered SPECT/CT bone imaging to use CT as the frame-of-reference during image reconstruction. The higher image resolution achieved from xSPECT Bone™ technology enables you to better localize and characterize disease for a more accurate representation of each patient’s condition.

As patient populations continue to age, the growing presence of metal implants and pacemakers adds complexity to imaging. iMAR, our CT metal-artifact-reduction technique, helps improve both CT and SPECT attenuation correction in these cases.2 xSPECT Bone and iMAR can easily be combined for even greater image clarity.
 

Dose reduction without compromise

For quick and conclusive answers to clinical questions, you need the best image for each patient. However, striking the right balance between image quality and radiation dose can be a challenge, particularly given today’s diverse patient population. Our proprietary CT image reconstruction software and hardware, SAFIRE, lets you accomplish this—quickly and easily.3

 

The right care at the right time

Adding reliable quantification to your clinical routine can facilitate quicker consensus and generate greater consistency across your institution. Our xSPECT Quant™ and Broad Quantification™ technologies generate highly accurate and reliable measurements to support early diagnoses and optimal therapeutic strategies for a wide array of clinical indications.

 

Technical Specifications

 

Gantry

 

Tunnel opening

70 cm

Tunnel length

89 cm

CT

 

Generator power

50 kW

Rotation time

up to 0.5 s

Tube voltage

80, 110, 130 kv

Iterative reconstruction

SAFIRE3, 4

Metal artifact reduction

iMAR2, 4

Slices

16/321

SPECT

 

Crystal thickness

3/8” or 5/8”

Detector dimension (FOV)

53.3 x 38.7 cm

Energy range

35-588 keV

System Sensitivity (LEHR at 10 cm)

202 cpm/μCi

Acquisition modes

Static, dynamic, gated, SPECT, gated SPECT, dynamic SPECT, whole-body, whole-body SPECT, SPECT/CT, xSPECT™

Quantitative accuracy

≤ 5%4, 5

 

More Information

Downloads

        . Symbia Intevo Bold Brochure  3 MB

        . Symbia Intevo Brochure  6 MB

        . Cybersecurity flyer  2 MB